Download Curriculum Vitae Dr. Andreas Spiegelberg (PDF 137 K)
Curriculum Vitae
1952 Born in Hamburg
1971-1979 Student of Mechanical Engineering at Universities in Karlsruhe and Berlin
1979-1986 Research work in the design of artificial hearts, Free University of Berlin
1980 Visiting fellow, University of California, San Francisco
1981 Visiting fellow, University of Utah, Salt Lake City
1989 Degree Doctor of Engineering (Dr.-Ing.) given by the
Technical University of Berlin
1989-2013 Owner, Managing Director, and Chief Technology Officer of
Spiegelberg GmbH & Co. KG in Hamburg. Design, production,
and sales of monitors and catheters for the brain.
1996-2012 Quality Management Officer and Regulatory Affairs Officer of
Spiegelberg GmbH & Co. KG
Since 2013 Consultant for medical devices. Engineering, Research and
Development, QM-Systems and Regulatory Affairs
2014-2019 Academic Guest in The Interface Group at the Institute of
Physiology of the University of Zurich
Since 2019 Senior Scientist in The Interface Group at the Institute of
Physiology of the University of Zurich
Awards
2004 Innovation Award of the City of Hamburg given for the design of
antimicrobial ventricular catheters
2008 Award for Innovative Medical Technology from the German Federal
Ministry of Education and Reserach given for the development of
a new method for non-invasive blood pressure measurement
2009 Award for Innovative Medical Technology from the German Federal
Ministry of Education and Reserach given for the development of
a new catheter that prevents access of bacteria by means of a balloon
which fills up the inside of the catheter
Publications
Peer Reviewed Journal Publications
- Karimi, F.; Neufeld, E.; Fallahi, A., Boraschi, A.; Zwanenburg, J. J.; Spiegelberg, A.; Kurtcuoglu, V.; Kuster, N.:Theory for a non-invasive diagnostic biomarker for craniospinal diseases. NeuroImage: Clinical, 2023, 37, 103280.
- Boraschi, A.; Spiegelberg, A.; Karimi, F.; Graf, K.; Fallahi, A.; Neufeld, E.; Kuster, N.; Kurtcuoglu, V.: The effect of body position change on noninvasively acquired intracranial pulse waves. Physiological Measurement, 2023, 44(3), 035014
- Spiegelberg, A.; Boraschi, A.; Karimi, F.; Capstick, M.; Fallahi, A.; Neufeld, E.; Kuster, N.; Kurtcuoglu, V.; Noninvasive Monitoring of Intracranial Pulse Waves. IEEE Transactions on Biomedical Engineering, 2022
- Spiegelberg, A.; Krause, M.; Meixensberger; J.; Kurtcuoglu, V.: RAQ: a novel surrogate for the craniospinal pressure–volume relationship. Physiological Measurement, 2020, 41(9), 094002
- Spiegelberg, A.; Krause, M.; Meixensberger, J.; Kurtcuoglu, V.: RAQ – A noise-resistant calibration-independent compliance surrogate. In: Intracranial Pressure & Neuromonitoring XVII, 2020, In print.
- Spiegelberg, A.; Stieglitz, L. ; Kurtcuoglu, V.: Why hydrocephalus patients suffer when the weather changes. A new hypothesis.. In: Intracranial Pressure & Neuromonitoring XVII, 2020, In print.
- Spiegelberg, A.; Krause, M.; Meixensberger, J.; Seifert, B.; Kurtcuoglu, V.: Significant Association of Slow Vasogenic ICP Waves with Normal Pressure Hydrocephalus Diagnosis. In: Intracranial Pressure & Neuromonitoring XVI, 243-246, Springer, Cham, 2018
- Spiegelberg, A.; Preuss, M.; Kurtcuoglu, V.: B-Waves revisited, Interdisciplinary Neurosurgery: Advanced Techniques and Case Management, vol. 6, pp. 13 – 17, 2016.
- Oechtering, J.; Kirkpatrick, P.J. Ludolph, A.G.K.; Hans, F. J.; Sellhaus, B.; Spiegelberg, A. Krings, T.: Magnetic Microparticles for Endovascular Aneurysm Treatment: In Vitro and In Vivo Experimental Results. Neurosurgery 68, 2011, 1388–1398
- Freiman, T. M., Spiegelberg, A.: Mounting device for external cerebrospinal fluid drainage: The Freiburg Stativ. Acta Neurochirurgica, 150, 2008 (10), 1081-1085
- Sauer, I. M., Frank, J., Spiegelberg, A., Bücherl, E. S.: Ovalis TAH: Development and In Vitro Testing of a New Electromechanical Energy Converter for a Total Artificial Heart. ASAIO J, 46, 2006, 744-748
- Piper, I.; Spiegelberg, A.; Whittle, I.; Singnorini, D.; Mascia, L.: A comparative study of the Spiegelberg Compliance Device with a manual volume-injection method: a clinical evaluation in patients with hydrocephalus. Brit J Neurosurg, 1999, 13(6), 581-6
- Whittle, I.; Spiegelberg, A.; Piper, I.: Experience Using the Spiegelberg Compliance Monitor in Patients with Hydrocephalus. Zentralblatt Neurochirurgie, (1997) Suppl, pg. 78.
- Spiegelberg, A.; Affeld, K.: Analyse von Herzschallsignalen als Mittel zur Störungserkennung. Kardiotechnik, 7, 1984, Heft 1, 15-17
- Spiegelberg, A.; Nielsen, S. D.: Softwareentwicklung für AIM 65 auf PDP 11. Micro Mag, Nr. 20, Aug. 1981, 26-31
- Spiegelberg, A.: Mikroprozessortechnik auf der Elektronika 1978. f. wirtschaftliche Fertigung, 74, 1979, 178-179
- Popken, W.; Spiegelberg, A.: Hilfsmittel für die Programmierung von Mikroprozessoren. f. wirtschaftliche Fertigung, 74, 1979, 402-420
Book Chapters
- Spiegelberg, A.; Moskopp, D.: Monitoring des Intrakraniellen Druckes. In: Moskopp, D.; Wassmann, H.-D: Neurochirurgie. Handbuch für die Weiterbildung und interdisziplinäres Nachschlagewerk. Schattauer, Stuttgart, New York, 2015, 2nd edition, pp. 118-125
- Spiegelberg, A.: Monitoring Intracranial Pressure. Hospital Management International 91, London, 1991, 462-463
Conference Proceedings
- Spiegelberg, A.; Kurtcuoglu, V.: RAQ – ein störungsresistenter kalibrierungsunabhängiger Complianceparameter 43. Jahrestagung der Sektion Intrakranieller Druck, Hirndurchblutung und Hydrozephalus der Deutschen Gesellschaft für Neurochirurgie (DGNC), 2017
- Spiegelberg, A.; Krause, M.; Kurtcuoglu, V.: ICP pulse amplitude modulation by respiration is increased in aqueduct stenosis. Hydrocephalus 2017
- Spiegelberg, A.; Preuss, M.; Meixensberger, J.; Kurtcuoglu, V.: Signifikante Assoziation von B-Wellen im ICP mit der Diagnose Aquäduktstenose. 42. Jahrestagung der Sektion Intrakranieller Druck, Hirndurchblutung und Hydrozephalus der Deutschen Gesellschaft für Neurochirurgie (DGNC), Abstracts, 2016
- Spiegelberg, A.; Preuss, M.; Meixensberger, J.; Seifert, B.; Kurtcuoglu, V.: Significant Association of Slow Vasogenic ICP Waves with Normal Pressure Hydrocephalus Diagnosis. 16th International Conference on Intracranial Pressure & Brain Monitoring (ICP), Booklet, 2016, 359-360
- Kirkpatrick, P.J.; Spiegelberg, A.; Krings, T.: Use of magnetically steered nanoparticles to treat vascular aneurysms – a proof of concept study. 13th EANS Congress of the European Association of Neurosurgical Societies. 2007, LXXXIV
- Spiegelberg, A.; Krüger, B.; Wedler, W.; Hilgendorff, V.; Affeld, K.: Eine neue Methode für die epidurale Messung des intracraniellen Druckes. 5. Treffpunkt Medizintechnik, Berlin, 1990 58-61
- Schichl, K.; Affeld, K.; Spiegelberg, A.; Mohnhaupt, A: Ein rechnergesteuerter Prüfstand für künstliche Herzklappen. Biomedizinische Technik 34, Erg., 1989, 95-96
- Körner, J. M.; Spiegelberg, A.; Wedler, W.: Ein neues Gerät zur Überwachung der Atmung von Kleintieren bei Injektions- und Intubationsnarkosen. Biomedizinische Technik 34, Erg., 1989, 105-106
- Affeld, K.; Spiegelberg, A.; Hilgendorff, V.: Verfahren für die zuverlässige Messung des venösen Druckes. 4. Treffpunkt Medizintechnik, Berlin 1989, 82-83
- Spiegelberg, A.; Wedler, W.; Körner, J. M.: Ein neues Gerät zur Überwachung der Atmung von Kleintieren bei Injektions- und Intubationsnarkosen. 4. Treffpunkt Medizintechnik, Berlin, 1989 ,408-409
- Affeld, K.; Spiegelberg, A.; Mohnhaupt, A.; Frank, J.; Bagheri, M.: A Portable and Partially Redundant Driver for the Artificial Heart. Proc. Europ. Soc. f. Artif. Organs, 1988
- Affeld, K.; Schichl, K.; Spiegelberg, A.; Mohnhaupt, A.: Rechnergesteuerter Prüfstand für künstliche Herzklappen. 3. Treffpunkt Medizintechnik, Berlin 1987, 54-55
- Hilgendorff, V.; Spiegelberg, A.; Affeld, K.: Druckmessung im Organismus mit dem Luftkapselkatheter. Acta chir. Austriaca, 1987, Heft 2, 515-516
- Affeld, K., Spiegelberg, A.; Schichl, K.; Mohnhaupt, A.: Design of a new Tester for Artificial Heartvalves. Life Support Systems, 4, 1986, Sup. 2, 142-144
- Hilgendorff, V.; Spiegelberg, A.; Affeld, K.: Der Luftkapselkatheter – Eine Methode zur Messung geringer intracorporaler Drücke, Biomedizinische Technik, 31, Erg., 1986, 72-73
- Affeld, K.; Frank, J.; Mohnhaupt, A.; Spiegelberg, A.: The Aircapsule Pressure Measurement System -Technical Foundations and Ten Years of Experience. Proc. Zhejiang ’85 Workshop on Biomedical Engineering, 1985, 8-16
- Spiegelberg, A.; Affeld, K.: A Model for the Generation of Intestinal Sounds. Proc. Zhejiang ’85 Workshop on Biomedical Engineering, 1985, 184-197
- Kitamura, T.; Spiegelberg, A.; Frank, J.; Mohnhaupt, A.; Affeld, K.: A Control and estimation Technique of the Portable Total Artificial Heart Driver. 9th IFAC World Congress 1984, Budapest
- Affeld, K.; Mohnhaupt, A.; Spiegelberg, A.; Friedrichsen, U.; Hilgendorff, V.: Progress in Measuring the Blood Pressure. Technical Developments for the Artificial Heart, Second World Symposium Artificial Heart, Berlin 1984, 85-94
- Keltz, P. D.; Pfeil, C. N.; Gertz, E. W.; Spiegelberg, A.: Integration of Hardware and Software Subsystems for the Medical Computer Environment. Proc. 15. Hawaii intern. Conf. on System Sciences, 1982, Vol. II, 370-379
- Spiegelberg, A.; Nielsen, S. D.; Affeld, K.; Frank, J.; Olsen, D. B.: Mikroprozessorgestützte Messung des Herzzeitvolumens bei Kälbern mit pneumatischen künstlichen Herzen. Biomed. Technik, 26, Erg., 1981, 103-104
- Spiegelberg, A.; Keltz, P. D.; Hollenberg, M.; Gertz, E. W.: Eine Computerkonfiguration für die klinische Weiterentwicklung eines Belastungs-EKG Indexes. Biomed. Technik, 26, Erg., 1981, 42-43
- Spiegelberg, A., Affeld, K.; Michel, U.; Bücherl, E. S.: Analyse von Schallsignalen als Mittel zur Störungserkennung beim künstlichen Herzen. Biomed. Technik, 25, Erg., 1980, 256-258
Published Patents and Patent Applications
- Spiegelberg, A.; Stensen, W.; Svendsen, J.S.: ANTIMICROBIAL FORMULATIONS COMPRISING SILICONE. European Patent Authority, EP000004164385A1, 2023
- Spiegelberg, A.; Stensen, W.; Svendsen, J.S.: FORMULAÇÕES ANTIMICROBIANAS COMPREENDENDO SILICONE, Brazilian Patent Authority, BR112022025172A2, 2023
- Spiegelberg, A.; Stensen, W.; Svendsen, J.S.: ANTIMICROBIAL FORMULATIONS COMPRISING SILICONE. Korean Patent Authority, KR102023022248A, 2023
- Spiegelberg, A.; Stensen, W.; Svendsen, J.S.: ANTIMICROBIAL ARTICLES COMPRISING POLYURETHANE, World Intellectual Property Organization, WO002022263475A1, 2022
- Beck, J.; Spiegelberg, A.: Ventil zum dauerhaften Implantieren, insbesondere zur Behandlung der Normaldruck-Hydrozephalus-Erkrankung, European Patent Authority, EP000003902592A1, 20
- Spiegelberg, A.; Stensen, W.; Svendsen, J.S.: ANTIMICROBIAL FORMULATIONS COMPRISING SILICONE. World Intellectual Property Organization, WO002021250286A1, 2021
- Spiegelberg, A.; Stensen, W.; Svendsen, J.S.: ANTIMICROBIAL FORMULATIONS COMPRISING SILICONE, Canadian Patent Authority, CA000003180562A1, 2021
- Beck, J.; Spiegelberg, A.: VALVE FOR PERMANENT IMPLANTATION, IN PARTICULAR FOR TREATMENT OF NORMAL PRESSURE HYDROCEPHALUS, US Patent and Trademark Authority, US020220072285A1, 2022
- Spiegelberg, A.: EINRICHTUNG ZUR DRAINAGE, INSBESONDERE ZUR DRAINAGE EINES CHRONISCHEN SUBDURALEN HÄMATOMS. European Patent Authority, EP000003302599B1, 2021
- Beck,; Spiegelberg, A.: Ventil zum dauerhaften Implantieren, insbesondere zur Behandlung der Normaldruck-Hydrozephalus-Erkrankung, World Intellectual Property Organization, WO002020136278A1, 2020
- Beck,; Spiegelberg, A.: Ventil zum dauerhaften Implantieren, insbesondere zur Behandlung der Normaldruck-Hydrozephalus-Erkrankung, Deutsches Patent- und Markenamt, DE102018133691A1, 2020
- Kurtcuoglu, V.; Spiegelberg, A.: DEVICE FOR DETERMINING A PARAMETER FOR DIAGNOSING HYDROCEPHALUS AND OTHER DISORDERS OF INTRACRANIAL PRESSURE, US Patent Authority, US020200196884A1 2020
- Kurtcuoglu, V.; Spiegelberg, A.: Einrichtung zur Bestimmung einer Kenngröße zur Diagnose des Hydrozephalus und anderer Störungen des Hirndrucks. European Patent Authority, EP000003621513A1 , 2020
- Kurtcuoglu, V.; Spiegelberg, A.: Einrichtung zur Bestimmung einer Kenngröße zur Diagnose des Hydrozephalus und anderer Störungen des Hirndrucks. Deutsches Patent- und Markenamt, DE102018100697A1, 2018
- Kurtcuoglu, V.; Spiegelberg, A.: Einrichtung zur Bestimmung einer Kenngröße zur Diagnose des Hydrozephalus und anderer Störungen des Hirndrucks. World Intellectual Property Organization, WO002018206799A1, 2018
- Spiegelberg, A.: DEVICE FOR DRAINAGE, IN PARTICULAR FOR THE DRAINAGE OF A CHRONIC SUBDURAL HEMATOMA. US Patent Autority, US020180140754A1, 2018
- Spiegelberg, A.: EINRICHTUNG ZUR DRAINAGE, INSBESONDERE ZUR DRAINAGE EINES CHRONISCHEN SUBDURALEN HÄMATOMS. European Patent Authority, EP000003302599A1, 2018
- Spiegelberg, A.: EINRICHTUNG ZUR DRAINAGE, INSBESONDERE ZUR DRAINAGE EINES CHRONISCHEN SUBDURALEN HÄMATOMS. Deutsches Patentamt, DE102015108754B1, 2018
- Spiegelberg, A.: DEVICE FOR DRAINAGE, IN PARTICULAR FOR THE DRAINAGE OF A CHRONIC SUBDURAL HEMATOMA. State Intellectual Property Office of the People’s Republic of China, CN000107666917A, 2018
- Spiegelberg, A.; Stieglitz, L.: Einrichtung zum Verschliessen eines Bohrloches und Befestigen einer Leitung. World Intellectual Property Organization, WO002017064151A1, 2017
- Spiegelberg, A.; Stieglitz, L.: Einrichtung zum Verschliessen eines Bohrloches und Befestigen einer Leitung. Deutsches Patentamt, DE102015117326A1, 2017Spiegelberg, A.: DEVICE FOR DRAINAGE, IN PARTICULAR FOR
- DRAINAGE OF A CHRONIC SUBDURAL HEMATOMA. DEVICE FOR DRAINAGE, IN PARTICULAR FOR DRAINAGE OF A CHRONIC SUBDURAL HEMATOMA. World Intellectual Property Organization, WO002016192705A1, 2016
- Kirkpatrick, P.; Spiegelberg, A.: Schädelprothese und Verfahren zum Verschließen. Deutsches Patentamt, DE102015107646A1, 2016
- Spiegelberg, A.: VORRICHTUNG ZUR DRAINAGE VON KÖRPERFLÜSSIGKEITEN, [EN] DEVICE FOR DRAINING BODY FLUIDS, [FR] DISPOSITIF POUR DRAINER DES LIQUIDES ORGANIQUES, World Intellectual Property Organization, WO002013182461A1, 2013
- Spiegelberg, A.: Verfahren zur Herstellung eines steril verpackten, metallhaltigen Kunststoffkörpers mit antimikrobiell wirkender Oberfläche, Deutsches Patentamt, DE102005053295C5, 2013
- Spiegelberg, A.; Stieglitz, L. H.: SAUG- UND BEWÄSSERUNGSVORRICHTUNG SUCTION AND IRRIGATION DEVICE SYSTÈME D’ASPIRATION ET D’IRRIGATION. European Patent Authority, EP000002643032A1, 2013
- Spiegelberg, A.; Stieglitz, L. H.: Suction and Irrigation Device. State Intellectual Property Office of the People’s Republic of China, CN000103391791A, 2013
- Spiegelberg, A.; Stieglitz, L. H.: Suction and Irrigation Device. US Patent Autority, US020130303979A1, 2013
- Spiegelberg, A.: Vorrichtung zur Drainage von Körperflüssigkeiten. Deutsches Patent- und Markenamt, DE102012209405A1, 2013
- Spiegelberg, A.; Stieglitz, L. H.: SUCTION AND IRRIGATION DEVICE, SYSTÈME D’ASPIRATION ET D’IRRIGATION. World Intellectual Property Organization, WO002012069592A1, 2012
- Spiegelberg, A.: Verfahren zur Herstellung eines steril verpackten, metallhaltigen Kunststoffkörpers mit antimikrobiell wirkender Oberfläche, Deutsches Patentamt, DE102005053295B4, 2009
- Kirkpatrick, P.; Spiegelberg, A.: Verwendung von magnetischen CS-Kapseln und/oder Mikrokapseln für die Behandlung von Aneurysmen. Deutsches Patentamt, DE102006049837A1, 2008
- Kirkpatrick, P.; Spiegelberg, A.: VERWENDUNG VON MAGNETISCHEN CS -KAPSELN UND/ODER MIKROKAPSELN FÜR DIE BEHANDLUNG VON ANEURYSMEN, USE OF MAGNETIC CS CAPSULES AND/OR MICRO
- CAPSULES FOR THE TREATMENT OF ANEURYSMS. World Intellectual Property Organization, WO002008049537A1, 2008
- Spiegelberg, A.: Verfahren zur Herstellung eines steril verpackten, metallhaltigen Kunststoffkörpers mit antimikrobiell wirkender Oberfläche, Deutsches Patentamt, DE102005053295A1, 2007
- Bücherl, E. S.; Frank, J.; Sauer, I. M.; Spiegelberg, A.: Artificial heart driving device. US Patent Office, US000005976184A, 1999
- Bücherl, E. S.; Frank, J.; Sauer, I. M.; Spiegelberg, A.: Antriebsvorrichtung für ein künstliches Herz. Deutsches Patentamt, DE000019505512C2, 1998
- Spiegelberg, A.: [DE] Verfahren und Einrichtung zur Bestimmung der Volumenelastizität des Inhaltes eines Hohlkörpers [EN] Determination system for elasticity of volume of content of human brain cavity. Deutsches Patentamt,DE000019637141A1, 1998
- Spiegelberg, A.: Einrichtung zur Bestimmung einer physikalischen Größe im Inneren eines abgeschlossenen Raumes Deutsches Patentamt, DE000019637140A1, 1998
- Bücherl, E. S.; Frank, J.; Sauer, I. M.; Spiegelberg, A.: ANTRIEBSVORRICHTUNG FÜR EIN KÜNSTLICHES HERZ, ARTIFICIAL HEART DRIVING DEVICE, DISPOSITIF D’ENTRAINEMENT POUR COEUR ARTIFICIEL. European Patent Office, EP000000808183B1, 1998
- Bücherl, E. S.; Frank, J.; Sauer, I. M.; Spiegelberg, A.: ANTRIEBSVORRICHTUNG FÜR EIN KÜNSTLICHES HERZ, Austrian Patent Office, AT000000173406E, 1998
- Bücherl, E. S.; Frank, J.; Sauer, I. M.; Spiegelberg, A.: ANTRIEBSVORRICHTUNG FÜR EIN KÜNSTLICHES HERZ ARTIFICIAL HEART DRIVING DEVICE DISPOSITIF D’ENTRAINEMENT POUR CEUR ARTIFICIEL. European Patent Office, EP000000808183A1, 1997
- Bücherl, E. S.; Frank, J.; Sauer, I. M.; Spiegelberg, A.: ANTRIEBSVORRICHTUNG FÜR EIN KÜNSTLICHES HERZ ARTIFICIAL HEART DRIVING DEVICE DISPOSITIF D’ENTRAINEMENT POUR COEUR ARTIFICIEL. World Intellectual Property Organization. WO001996024394A1, 1996
- Bücherl, E. S.; Frank, J.; Sauer, I. M.; Spiegelberg, A.: Antriebsvorrichtung für ein künstliches Herz. Deutsches Patentamt, DE000019505512A1, 1996Pauldrach, G.; Spiegelberg, A.: Süß, W.: Einrichtung zum Einführen einer Magensonde. Deutsches Patentamt, DE000004237750A1, 1994
- Spiegelberg, A.: Magensonde. Deutsches Patentamt, DE000004212554A1, 1993
- Spiegelberg, A.: Magensonde. Deutsches Patentamt, DE000009207153U1, 1993
- Spiegelberg, A.: Hydrocephalusventil. Deutsches Patentamt DE000004026202A1, 1992
- Affeld, K.; Hilgendorff, V.; Spiegelberg, A.: EINRICHTUNG ZUR DRUCKMESSUNG. INSTALLATION FOR PRESSURE MEASUREMENT. INSTALLATION POUR MESURER LA TENSION. European Patent Office, EP000000208746A1, 1987
- Mohnhaupt, A.; Spiegelberg, A.: VERFAHREN UND EINRICHTUNG ZUR DIGITALISIERUNG VON KONTUREN, Method and device for digitising contours. Deutsches Patentamt, DE000003530786A1, 1987
- Affeld, K.; Hilgendorff, V., Spiegelberg, A.: Einrichtung zur Druckmessung. European Patent Office, EP000000208746A1 , 1987
- Affeld, K.; Hilgendorff, V., Spiegelberg, A.: Einrichtung zur Druckmessung. Deutsches Patentamt, DE000003500822A1, 1986
- Affeld, K.; Hilgendorff, V.; Spiegelberg, A.: INSTALLATION FOR PRESSURE MEASUREMENT. World Intellectual Property Organization. WO001986003957A1, 1986